Latest News

Successful testing Sandwich A60 panel

Posted by Van Dam on 25 April 2016

Recently Van Dam has successfully tested and approved our newly developed sandwich panel system (according IMO SOLAS) based on the A60 fire curve and test specifications. The Test subject was successful on both temperature and integrity.

According testing requirements, there was no sign of flames on the “cold-side” (integrity spec)
After 60 minutes the maximum temperature was only 138,5 degrees centigrade (temperature spec, max allowed temperature cold side 180 degrees centigrade IMO specification)
The second insulation specification is, that the test sample cannot exceed an average of 140 degrees centigrade on the cold-side.

160425-testing-sandwich-a60-panel.jpg

Test Sample in oven during testing.

160425-after-test-sandwich-a60-panel.jpg

Bulging of the sandwich panel after the test securing integrity and temperature.

Our newly developed sandwich panel is pre-fabricated and an completely finish building element with a total thickness of 100mm. With an Rockwool insulated passive fire protective core and 0,75 mm steel skin, allows the product to be able to achieve big spans.

Main USP’s of Van Dam Sandwich A60 panel are:

  • Dividing inner and outer climate in one solution and with one product
  • Finish of the wall system on both sides
  • Very High thermal values
  • Fast and easy installation
  • Lightweight
  • Good acoustic values and reduction (32 dB)
  • Good fire resisting capabilities (suitable up to A60 offshore applications)
  • Good thermal resistancy
Share on social media: